隨著使用時間的不斷增長,濟南通風(fēng)管道會積累大量的雜質(zhì)。這些雜質(zhì)會在管道中停留很長一段時間,并在運行過程中加速油的凝結(jié)。溫度轉(zhuǎn)換過高,會對氣動閥、液壓元件造成損壞,對正常運行有很大影響。因此,有必要定期清理通風(fēng)管道設(shè)備。如何清潔它?濟南通風(fēng)管道為您介紹一下吧。
With the continuous growth of service time, a large number of impurities will be accumulated in Jinan ventilation pipeline. These impurities will stay in the pipeline for a long time and accelerate the oil condensation during operation. Too high temperature conversion will damage the pneumatic valve and hydraulic components, and have a great impact on normal operation. Therefore, it is necessary to clean the ventilation pipe equipment regularly. How to clean it? Jinan ventilation pipe for you to introduce it.
(1)風(fēng)道與風(fēng)機連接時,進、出風(fēng)口應(yīng)安裝軟接頭。軟接頭的截面尺寸應(yīng)與風(fēng)機進出口截面尺寸一致。軟管連接可由帆布、人造革和其他材料制成。軟管長度不應(yīng)小于200,并應(yīng)適當(dāng)擰緊。軟管可以緩沖風(fēng)扇的振動。
(1) When the air duct is connected with the fan, soft joints shall be installed at the air inlet and outlet. The section size of soft joint shall be consistent with that of fan inlet and outlet. Hose connections can be made of canvas, leatherette, and other materials. The hose length shall not be less than 200 and shall be properly tightened. The hose dampens the vibration of the fan.
(2)風(fēng)管與除塵設(shè)備、加熱設(shè)備連接后,根據(jù)理論映射圖安裝好設(shè)備后,應(yīng)暫停預(yù)制安裝。
(2) After the air duct is connected with the dedusting equipment and heating equipment, the prefabricated installation shall be suspended after the equipment is installed according to the theoretical mapping diagram.
(3)濟南風(fēng)管安裝時,風(fēng)管預(yù)制好后,應(yīng)打開進、出口。如果需要在安裝結(jié)束時打開管道,則連接應(yīng)緊密。
(3) When Jinan air duct is installed, the inlet and outlet shall be opened after the air duct is prefabricated. If it is necessary to open the pipe at the end of installation, the connection shall be tight.
(4)輸送高含水率凝結(jié)水或氣體時,水平管道應(yīng)設(shè)置在斜坡處,并在低處與排水管連接。安裝時風(fēng)管底部不應(yīng)有縱向接縫,底部接縫處應(yīng)懸掛密封處理。
(4) When transporting condensate or gas with high moisture content, the horizontal pipeline shall be set at the slope and connected with the drainage pipe at the low position. During installation, there shall be no longitudinal joint at the bottom of the air duct, and the bottom joint shall be hung for sealing.
(5)輸送易燃易爆氣體的鋼板風(fēng)道,在風(fēng)道連接法蘭處安裝跳線,并與靜電接地網(wǎng)連接。
(5) For the steel plate air duct conveying inflammable and explosive gas, install jumpers at the connecting flange of the air duct and connect with the electrostatic grounding grid.
(6)水平風(fēng)道高度在4m以上時,安裝人員應(yīng)系好安全帶。腳手架或活動支架上的跳板應(yīng)固定,跳板寬度應(yīng)符合安全規(guī)范,腳手架上的設(shè)備人員應(yīng)隨身攜帶物品袋,避免物品或電鉆等掉落傷人。
(6) When the height of horizontal air duct is more than 4m, the installation personnel shall fasten the safety belt. The springboard on the scaffold or movable support shall be fixed, and the width of the springboard shall meet the safety specifications. The equipment personnel on the scaffold shall carry the bag with them to avoid personal injury caused by falling objects or electric drills.
(7)雙臂臂架在風(fēng)洞內(nèi)就位后,叉骨要直,臂架不要換,雙臂臂架受力均勻。
(7) After the double arm boom is in place in the wind tunnel, the fork bone shall be straight, the boom shall not be replaced, and the force on the double arm boom shall be uniform.
濟南通風(fēng)管道良好,每三個月清洗一次,既能保證正常運行,又能延長通風(fēng)管道的使用壽命。
Jinan ventilation pipeline is good and cleaned every three months, which can not only ensure normal operation, but also extend the service life of the ventilation pipeline.
上一篇:通風(fēng)設(shè)備沾灰的原因以及措施介紹!
下一篇:螺旋風(fēng)管應(yīng)該如何面對寒冷天氣?